Input Voltage |
90 - 264 VAC (127 - 370 VDC) |
Input Frequency |
47 - 63 Hz |
Inrush Current |
< 60 Amps; Measured at 264 VAC, 25°C Ambient, Cold start |
No Load Power |
< 0.5 W ; 115 VAC input |
Output Voltage |
12 V to 48 V |
Output Power |
350 W |
Voltage Tolerance |
± 1 % |
Line Regulation |
± 0.5 |
Load Regulation |
± 1 % |
Turn On Time |
< 2 sec at full load |
Hold Up Time |
> 20 msec at convection load & > 10 msec at full load for nominal Vout |
Rise Time |
< 100 ms |
Fan output |
12 V, 0.5 A output is available on a 2 pin connector header |
Overload Protection |
110 % to 140 % of rated output current; Hiccup type; Autorecovery |
Overvoltage Protection |
Latched type; Input AC power to be recycled to recover the power supply |
Output Short Circuit Protection |
Hiccup mode when output is shorted; Autorecovery type |
Over Temperature Protection |
Power supply shuts down when the temperature of PCB below main transformer reaches typically 120°C;Turns on only after the temperature falls below 90°C typically and AC power is recycled thereafter |
Operating Temp |
- 25°C to + 70°C; De-rate linearly above 50°C from 100 % load at 50°C to 50 % load at 70°C,- 25°C to 0°C start-up is guaranteed with specification deviation |
Storage Temp |
- 40°C to + 85°C |
Cooling |
Natural convection cooled or Forced Air cooled as per power requirements |
Humidity |
5 to 95 % RH, Non condensing |
Altitude |
2000 m |
Dimension |
5” x 3” x 1.16” (L x W x H); Height above PCB: 1” |
Weight |
< 300 gms |
Mounting |
Open Frame |