OPS 60W Series

Product: OPS2x4-60
  • 4 x 2 x 1.16 Inches Form factor
  • 60 Watts Convection
  • Efficiencies up to 87 %
  • - 40°C to + 70°C operating temperature
  • Medical (BF) Safety Approvals
  • No Load Power < 0.5W
  • Approved to Household, ITAV and Medical standards

BRIEF SPECIFICATIONS

Input Voltage 90 - 264 VAC (127 - 370 VDC)
Input Frequency 47 - 63 Hz
Inrush Current < 60 Amps; Measured at 264 VAC, 25°C Ambient, Cold start
No Load Power < 0.5 W ; 115 VAC input
Output Voltage 5 V to 48 V
Output Power 60 W
Voltage Tolerance ± 1 %
Line Regulation < 1% of Vout
Load Regulation ± 1 %
Turn On Time < 3 sec @ Full load
Hold Up Time ≥60ms at 230V AC & ≥15ms at 115V AC, Full load
Rise Time < 100 ms
Overload Protection > 110% of rated output current; Hiccup type; Autorecovery
Overvoltage Protection Latched type; Input AC power to be recycled to recover the power supply
Output Short Circuit Protection Hiccup mode when output is shorted; Autorecovery type
Over Temperature Power supply shuts down when the temperature of PCB below main transformer reaches typically 120°C
Operating Temp -40°C to +70°C; De-rate linearly above 50°C from 100% load at 50°C to 50% load at 70°C
Note : Only start up guaranteed at -40°C with spec deterioration
Storage Temp - 40°C to + 85°C
Cooling Natural convection cooled
Humidity 5 to 95 % RH, Non condensing
Altitude 2000 m
Dimension 4” x 2” x 1.16” (L x W x H); Height above PCB: 1”
Weight < 150 gms
Mounting Open Frame

Product Variants

Product Code Description Certification
OPS2x4-60-05-A-1-CU Open Frame Power Supply with 4 x 2 x 1.16 Inches Form factor, 5V, 10A, 50 Watts with Convection Cooling UL, CB
OPS2x4-60-12-A-1-CU Open Frame Power Supply with 4 x 2 x 1.16 Inches Form factor, 12V, 5A, 60 Watts with Convection Cooling UL, CB
OPS2x4-60-15-A-1-CU Open Frame Power Supply with 4 x 2 x 1.16 Inches Form factor, 15V, 4A, 60 Watts with Convection Cooling UL, CB
OPS2x4-60-24-A-1-CU Open Frame Power Supply with 4 x 2 x 1.16 Inches Form factor, 24V, 2.5A, 60 Watts with Convection Cooling UL, CB
OPS2x4-60-48-A-1-CU Open Frame Power Supply with 4 x 2 x 1.16 Inches Form factor, 48V, 1.25A, 60 Watts with Convection Cooling UL, CB